BioInfoBank Library


 
author name recommending commenting favorite    papers recom. cited
0 0 0 1 0 1 [Update]
0 0 0 2 0 1 [Update]
0 0 0 1 0 0 [Update]
0 0 0 2 0 0 [Update]
0 0 0 1 0 0 [Update]

Latest Paper:

go to Publishergo to Pubmedgo to Scholargo to Googleshow EndNote Citationshow BibTex Citation
Århus University, Department of Bioscience, Ole Worms Allé, Building 1135, 8000 Århus C, Denmark.
This paper reviews the state of the art in measuring, modeling, and managing clogging in subsurface-flow treatment wetlands. Methods for measuring in situ hydraulic conductivity in treatment wetlands are now available, which provide valuable insight into assessing and evaluating the extent of clogging. These results, paired with the information from more traditional approaches (e.g., tracer testing and composition of the clog matter) are being incorporated into the latest treatment wetland models. Recent finite element analysis models can now simulate clogging development in subsurface-flow treatment wetlands with reasonable accuracy. Various management strategies have been developed to extend the life of clogged treatment wetlands, including gravel excavation and/or washing, chemical treatment, and application of earthworms. These strategies are compared and available cost information is reported.
go to Publishergo to Pubmedgo to Scholargo to Googleshow EndNote Citationshow BibTex Citation
Department of Biochemistry, University of Washington, Seattle, Washington 98195, USA.
Past anthrax attacks in the United States have highlighted the need for improved measures against bioweapons. The virulence of anthrax stems from the shielding properties of the Bacillus anthracis poly-γ-d-glutamic acid capsule. In the presence of excess CapD, a B. anthracis γ-glutamyl transpeptidase, the protective capsule is degraded, and the immune system can successfully combat infection. Although CapD shows promise as a next generation protein therapeutic against anthrax, improvements in production, stability, and therapeutic formulation are needed. In this study, we addressed several of these problems through computational protein engineering techniques. We show that circular permutation of CapD improved production properties and dramatically increased kinetic thermostability. At 45 °C, CapD was completely inactive after 5 min, but circularly permuted CapD remained almost entirely active after 30 min. In addition, we identify an amino acid substitution that dramatically decreased transpeptidation activity but not hydrolysis. Subsequently, we show that this mutant had a diminished capsule degradation activity, suggesting that CapD catalyzes capsule degradation through a transpeptidation reaction with endogenous amino acids and peptides in serum rather than hydrolysis.
go to Publishergo to Pubmedgo to Scholargo to Googleshow EndNote Citationshow BibTex Citation
Department of Biomolecular Engineering, University of California Santa Cruz, 1156 High Street, Santa Cruz, CA 95064, USA.
Signal Transduction by Ion NanoGating (STING) is a label-free technology based on functionalized quartz nanopipettes. The nanopipette pore can be decorated with a variety of recognition elements and the molecular interaction is transduced via a simple electrochemical system. A STING sensor can be easily and reproducibly fabricated and tailored at the bench starting from inexpensive quartz capillaries. The analytical application of this new biosensing platform, however, was limited due to the difficult correlation between the measured ionic current and the analyte concentration in solution. Here we show that STING sensors functionalized with aptamers allow the quantitative detection of thrombin. The binding of thrombin generates a signal that can be directly correlated to its concentration in the bulk solution.
go to Publishergo to Pubmedgo to Scholargo to Googleshow EndNote Citationshow BibTex Citation
Jacques Whitford NAWE, 4444 Centerville Road, White Bear Lake, Minnesota 55127, USA; Current address: Helmholtz Centre for Environmental Research (UFZ), Permoserstrasse 15, 04318 Leipzig, Germany E-mail: jaime.nivala@gmail.com.
One of the most frequently encountered operational problems in subsurface-flow constructed wetlands is clogging. Traditionally, the restoration procedure is to remove the clogged gravel or sand and replace it with clean material. This method, while effective, is costly and may require sections of the facility to be taken offline for extended periods of time. Another common remediation strategy is to have a resting period for each wetland cell, although this is not an option for very small systems which often consist of only one treatment cell. Recently, a more radical approach has been tested on a number of lab-scale and pilot-scale setups which consists of an aggressive oxidation of organic matter by means of hydrogen peroxide (H(2)O(2)). Results indicate that after treatment, clogging was substantially reduced and that H(2)O(2) did not appear to have a long-term negative effect on plants and biofilms. The outcomes of two full-scale tests are discussed in this paper.
go to Publishergo to Pubmedgo to Scholargo to Googleshow EndNote Citationshow BibTex Citation
North American Wetland Engineering LLC, 4444 Centerville Road, Suite 140, White Bear Lake, Minnesota 55127 USA.
A pilot-scale subsurface-flow constructed wetland was installed at the Jones County Municipal Landfill, near Anamosa, Iowa, in August 1999 to demonstrate the use of constructed wetlands as a viable low-cost treatment option for leachate generated at small landfills. The system was equipped with a patented wetland aeration process to aid in removal of organic matter and ammonia nitrogen. The high iron content of the leachate caused the aeration system to cease 2 years into operation. Upon the installation of a pretreatment chamber for iron removal and a new aeration system, treatment efficiencies dramatically improved. Seasonal performance with and without aeration is reported for 5-day biochemical oxygen demand (BOD(5)), chemical oxygen demand (COD), ammonia nitrogen (NH(4)-N), and nitrate nitrogen (NO(3)-N). Since winter air temperatures in Iowa can be very cold, a layer of mulch insulation was installed on top of the wetland bed to keep the system from freezing. When the insulation layer was properly maintained (either through sufficient litterfall or replenishing the mulch layer), the wetland sustained air temperatures of as low as -26 degrees C without freezing problems.
Polish News
2012-05-17 16:48:57 © BioInfoBank Institute