BioInfoBank Library


 
author name recommending commenting favorite    papers recom. cited
0 0 0 2 0 0 [Update]
0 0 0 1 0 7 [Update]

Latest Paper:

go to Pubmedgo to Scholargo to Googleshow EndNote Citationshow BibTex Citation
Lawrence Livermore National Laboratory, Livermore, California 94550, USA. shverdin2@llnl.gov
We demonstrate a nonlinear crystal-based short pulse recirculation cavity for trapping the second harmonic of an incident high-power laser pulse. This scheme aims to increase the efficiency and flux of Compton-scattering-based light sources. We demonstrate up to 40x average power enhancement of frequency-doubled submillijoule picosecond pulses, and 17x average power enhancement of 177 mJ, 10 ps, 10 Hz pulses.
go to Publishergo to Pubmedgo to Scholargo to Googleshow EndNote Citationshow BibTex Citation
Lawrence Livermore National Laboratory, Livermore, California 94551, USA.
We describe a modification to a transmission electron microscope (TEM) that allows it to briefly (using a pulsed-laser-driven photocathode) operate at currents in excess of 10 mA while keeping the effects of condenser lens aberrations to a minimum. This modification allows real-space imaging of material microstructure with a resolution of order 10 nm over regions several microm across with an exposure time of 15 ns. This is more than six orders of magnitude faster than typical video-rate TEM imaging. The key is the addition of a weak magnetic lens to couple the large-diameter high-current beam exiting the accelerator into the acceptance aperture of a conventional TEM condenser lens system. We show that the performance of the system is essentially consistent with models derived from ray tracing and finite element simulations. The instrument can also be operated as a conventional TEM by using the electron gun in a thermionic mode. The modification enables very high electron current densities in microm-sized areas and could also be used in a nonpulsed system for high-throughput imaging and analytical TEM.
go to Publishergo to Pubmedgo to Scholargo to Googleshow EndNote Citationshow BibTex Citation
Materials Science and Technology Division, Chemistry and Materials Science Directorate, Lawrence Livermore National Laboratory, P.O. Box 808; L-356, Livermore, CA 94550, USA.
Although recent years have seen significant advances in the spatial resolution possible in the transmission electron microscope (TEM), the temporal resolution of most microscopes is limited to video rate at best. This lack of temporal resolution means that our understanding of dynamic processes in materials is extremely limited. High temporal resolution in the TEM can be achieved, however, by replacing the normal thermionic or field emission source with a photoemission source. In this case the temporal resolution is limited only by the ability to create a short pulse of photoexcited electrons in the source, and this can be as short as a few femtoseconds. The operation of the photo-emission source and the control of the subsequent pulse of electrons (containing as many as 5x10(7) electrons) create significant challenges for a standard microscope column that is designed to operate with a single electron in the column at any one time. In this paper, the generation and control of electron pulses in the TEM to obtain a temporal resolution <10(-6)s will be described and the effect of the pulse duration and current density on the spatial resolution of the instrument will be examined. The potential of these levels of temporal and spatial resolution for the study of dynamic materials processes will also be discussed.
Polish News
2012-05-23 09:49:00 © BioInfoBank Institute